KI-10200 Automatic Aniline Point Apparatus with Automated Sampling System

Test Method
Aniline point is used to characterize pure hydrocarbons and to indicate the aromatic content of hydrocarbon mixtures. Equal volumes of aniline and sample or sample plus n-heptane are stirred together while being heated at a controlled rate. After the two phases become miscible, the mixture is cooled at a controlled rate and the temperature at which the two phases separate is the aniline point or mixed aniline point of the sample.

Features and Benefits
• Conforms to ASTM D611 and related specifications

• For samples ranging from clear to very dark

• Temperature range 0° to 150°C (32 to 302°F)

• Digital temperature display
 

KI-10200 Automatic Aniline Point Apparatus
Performs aniline point and mixed aniline point determinations automatically by means of a modified thin film technique (ASTM D611 Method E). The sample-aniline mixture is directly heated by a platinum immersion heater and the aniline point is detected photoelectrically. Temperature is displayed on a large LED indicator. Built-in pressure regulator and solenoid valve permit the use of cooling air for quicker cooling cycles or to determine subambient aniline point temperatures. Aniline points as low as 0°C (32°F) can be determined with the use of refrigerated cooling air. Equipped with variable controls for heater, light source and stirrer speed. Cabinet exterior surfaces have a chemical resistant polyurethane enamel finish.

Automated Sampling System – Provides hands-free operation for aniline point determinations, preventing operator contact with the aniline, n-heptane, and test samples. Automatically adds exact volumes of the test components to the mixing chamber, followed by transfer of the test mixture to a waste container and rinsing of the mixing chamber with solvent at the completion of the test. Retrofit automated sampling system is available for existing aniline point systems. Please contact your PSSC representative for additional information.

Specifications
Conforms to the specifications of:
ASTM D611; IP 2; ISO 2977; DIN 51775; FTM 791-3601; NF M 07-021

Testing Range: 0 to 150°C (32 to 302°F)

Temperature Display: 0-999.9°C

Electrical Requirements
115V, 50/60Hz, Single Phase, 0.4A
220-240V, 50/60Hz, Single Phase, 0.2A

Included Accessories
Standard Pyrex™ Test Cell with drain

Dimensions lxwxh,in.(cm)
14.5x8.5x20.5 (37x22x53)
Net Weight: 32.5 lbs (14.7kg)

Shipping Information
Shipping Weight: 46 lbs (21kg)
Dimensions: 8.2 Cu. ft.

  Ordering Information
Catalog
Number
Product Description
Electrical Requirements
KI-10200 Automatic Aniline Point Apparatus 115V 50/60Hz
KI-10290 Automatic Aniline Point Apparatus 220-240V 50/60Hz
KI-10280 Automatic Sampling System 115-240V 50/60Hz
The KI-10280 Automatic Sampling System is factory installed on the KI-10200 and KI-10290 Automatic Aniline Point Apparatus or shipped separately as a retrofit for existing units.

  Accessories
Catalog
Number
Product Description
Temperature Range
250-000-33F
ASTM 33F Thermometer
-36.5 to +107.5°F
250-000-33C
ASTM 33C Thermometer
-38 to +42°C
250-000-34F
ASTM 34F Thermometer
77 to 221°F
250-000-34C ASTM 34C Thermometer
25 to 105°C
250-000-35F ASTM 35F Thermometer
194 to 338°F
250-000-35C ASTM 35C Thermometer
90 to 170°C
KI-10210 Pyrex Test Cell with drain
KI-10220
Heating-Cooling Tube with platinum element
When inquiring about NIST traceable certified thermometers, please refer to the catalog number for the corresponding thermometer and replace the middle three zeros in the catalog number with 004. Example: 251-000-01C ASTM 1C Thermometer would be 251-004-01C ASTM 1C Certified Thermometer.